Feedback

X
Investigations of After Cavity Interaction in Gyrotrons Including the Effect of Non-uniform Magnetic Field

Investigations of After Cavity Interaction in Gyrotrons Including the Effect of Non-uniform Magnetic Field

0 Ungluers have Faved this Work
Dynamic after-cavity interaction (ACI) in megawatt-class gyrotrons is investigated that could lead to lower output mode purity and increased level of internal stray radiation. The self-consistent KIT-IHM multi-mode-code SELFT has been modified to extend the simulation domain into the radius up-taper section of the gyrotron cavity where the probability of ACI exists. Studies on four different gyrotron configurations confirm that undesired interactions in the up-taper region can result in additional parasitic oscillations with relative power in the 1%-range.

This book is included in DOAB.

Why read this book? Have your say.

You must be logged in to comment.

Rights Information

Are you the author or publisher of this work? If so, you can claim it as yours by registering as an Unglue.it rights holder.

Downloads

This work has been downloaded 20 times via unglue.it ebook links.
  1. 20 - pdf (CC BY-SA) at Unglue.it.

Keywords

  • After-Cavity Interaction
  • Electron-Cyclotron-Heating
  • fusion plasmas
  • High-Power Gyrotron